Free VA-MP Practice Questions

10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.

Start the free practice test → ★★★★★4.9/5 from 2,400+ candidates · No signup

The VA-MP exam has 80 questions and runs 3 hours 30 minutes.

These 10 free VA-MP questions are organized by exam domain, so you can see how each part of the Virginia Master Plumber Exam blueprint is tested. Reveal the answer and explanation under each question.

Domain 3: Renewal and Reinstatement

Question 1

A Virginia master plumbing license expired 18 months ago. The holder has completed the required plumbing continuing education and has performed no regulated work since expiration. Which path applies?

Show answer & explanation

Correct answer: B - Use reinstatement; do not resume regulated work until the license is restored

Domain 5: Qualification for Licensure

Question 2

Which applicant, based only on the facts given, clearly satisfies a current Virginia route to sit for the master-level plumbing examination?

Show answer & explanation

Correct answer: C - A journeyman plumber who has held a valid journeyman license for 14 months

Domain 7: Drainage Waste and Vents

Question 3

A four-story building is designed with a 4-inch soil stack. The connected load is 300 DFU, and the most heavily loaded branch interval carries 95 DFU. For a 4-inch stack, the limits are 500 DFU total and 90 DFU in any one branch interval. How should the design be evaluated?

Show answer & explanation

Correct answer: B - Noncompliant; the 95-DFU branch interval exceeds the 90-DFU limit

Question 4

In a three-story building, only the basement restroom fixtures are below the elevation of the next upstream public-sewer manhole cover. All fixtures on the upper floors are above that elevation. How should backwater protection be arranged?

Show answer & explanation

Correct answer: D - Protect the basement branch; connect upper-floor fixtures downstream for gravity drainage

Question 5

A same-floor bathroom group is horizontally wet vented with a 2-inch branch. A kitchen sink from the adjacent room is connected into the wet-vented section between the lavatory and water closet. What is the defect?

Show answer & explanation

Correct answer: C - The kitchen sink cannot discharge into a horizontal wet vent serving only bathroom-group fixtures

Domain 8: Water Supply Systems

Question 6

A public water-closet flushometer is 50 feet above a 74-psi service entrance. Known meter and valve losses are 9 psi, and the proposed pipe size adds 10 psi of friction loss at design flow. Using 0.433 psi loss per foot of rise and a required 35-psi residual at the flushometer, is the proposed size adequate?

Show answer & explanation

Correct answer: D - No; after all losses, the outlet residual is about 33.4 psi, below the required 35 psi

Domain 9: Backflow Prevention

Question 7

A closed-loop boiler contains toxic treatment chemicals. Because the boiler can operate above the potable-supply pressure, its makeup connection is exposed to both a health hazard and backpressure. The equipment requires a direct pressurized connection. Which backflow protection is appropriate?

Show answer & explanation

Correct answer: A - A reduced-pressure-principle backflow prevention assembly (RPZ)

Domain 10: Storm Drainage Systems

Question 8

A low-slope roof has primary drains at the low points and secondary drains with inlets 2 inches higher. The secondary piping joins the primary leader before the leader exits the building. Which revision preserves the intended emergency function?

Show answer & explanation

Correct answer: B - Give the secondary system equal capacity and an independent, visible above-grade discharge

Domain 11: Plumbing Fixtures

Question 9

A prefabricated shower has an interior floor 28 inches by 34 inches, documented as 952 square inches, a 24-inch clear door opening, and adequate receptor slope. The minimums are 900 square inches of area, a 30-inch-diameter circle, and a 22-inch door opening. The shower is:

Show answer & explanation

Correct answer: C - Noncompliant: although the area and opening pass, a 30-inch circle cannot fit across the 28-inch dimension

Domain 12: General Regulations

Question 10

During rough-in, a copper tube passes through a stud with only 1 inch between the tube and the nearest face of the framing. What protection is required at that vulnerable location?

Show answer & explanation

Correct answer: A - A steel shield plate at least 0.0575 inch thick (No. 16 gage)

The rest of the VA-MP blueprint

The VA-MP exam also covers these domains. Drill them in the full free practice test:

That's 10 of 1,030

The full bank has 1,020 more VA-MP questions with explanations.

Continue in the free practice test →